Omega DP26-RTD Manuale Utente

Navigare online o scaricare Manuale Utente per Misurazione, test & controllo Omega DP26-RTD. Omega DP26-RTD User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - User’s Guide

DP26-RTDDifferential TemperatureMeter with RTDomega.com e-mail: [email protected] latest product manualsomegamanual.infoUSAMADE INUser’s GuideShop on

Pagina 2 - Servicing Europe:

2SECTION 1.2 SAFETY CONSIDERATIONSThis device is marked with the international caution symbol. It is important to read this manual before installing

Pagina 3 - Optional Procedures:

3SECTION 2. ABOUT THE METER2.1 DESCRIPTIONThe Differential RTD meter is a value packed indicator/controller. Four full digitsaccurately display your

Pagina 4

42.3 AVAILABLE ACCESSORIESTable 2.1 Accessories and Add-onsAdd-On OptionsFS Special Calibration/ConfigurationSPC4 NEMA-4 Splash Proof CoverSPC18 NEMA-

Pagina 5 - NOTES, WARNINGS and CAUTIONS

52.4 FRONT OF THE METERFigure 5-1 shows the location of each part of the front of the meter. Figure 2-1 Front PanelDigital LED Display: -1.9.9.9.

Pagina 6 - Table of Contents

62.4 FRONT OF THE METER (Continued)METER BUTTONSSETPTS Button In the run mode, press this button to sequentially recall the previous setpoint setting

Pagina 7

72.4 FRONT OF THE METER (Continued)MENU ButtonIn the run mode, press the MENU button to terminate the current measuring processand enter you into the

Pagina 8 - List of Tables

2.5 FRONT PANEL LOCKOUT2.5.1 PUSH BUTTON LOCKOUTTo lock the RESET, MENU and SETPTS buttons, verify that the S3-A jumper isinstalled and the S3-E jumpe

Pagina 9 - SECTION 1. INTRODUCTION

92.6 BACK OF THE METERFigure 2-2 shows the connector label mounted at the top of the meter housing. Table2-2 gives a brief description of each connec

Pagina 10

102.6 BACK OF THE METER (Continued)Table 2-2 Connector DescriptionConnector DescriptionTB1-1 Setpoint 1: Normally open (N.O.1) connectionTB1-2 Setpoin

Pagina 11 - SECTION 2. ABOUT THE METER

2.7 DISASSEMBLYYou may need to open up the meter for one of the following reasons:• To check or change the 115 or 230 Vac power jumpers.• To install

Pagina 12 - Accessories

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its pr

Pagina 13 - DEVT1/T2/SETPTS

SECTION 3. GETTING STARTEDCaution: The meter has no power-on switch, so it will be in operation assoon you apply power.If you power off/on the meter,

Pagina 14 - METER BUTTONS

3.2 MAIN BOARD POWER JUMPERS (Continued)Figure 3-2 shows the main board jumpers.Figure 3.2 Main Board Jumper PositionsFigure 3.3 Upper Option Board I

Pagina 15

3.2 MAIN BOARD POWER JUMPERS (Continued)S2 jumpers are for sensor break indications:* S2A jumper is not used* S2B jumper is for positive sensor break

Pagina 16 - 2.5 FRONT PANEL LOCKOUT

3.3 MOUNTING THE METERFigure 3-3 Meter - Exploded View1. Cut a hole in your panel, asshown in Figure 3-3. Forspecific dimensions refer toFigure 3-4.

Pagina 17 - (DIFFERENTIAL RTD)

3.4 CONNECTING SENSOR INPUTFigure 3-5 through 3-7 illustrate how to connect you power sensors.Figure 3-5 2-Wire RTD Input ConnectionFigure 3-6 3-Wir

Pagina 18

3.5 CONNECTING MAIN POWERConnect the ac main power connections as shown in Figure 3-8.Warning: Do not connect AC power to your device until you haveco

Pagina 19 - 2.7 DISASSEMBLY

3.5 CONNECTING MAIN POWER (Continued)Connect the dc main power connections as shown in Figure 3-9..Figure 3-9 Main Power Connections (dc powered unit

Pagina 20 - SECTION 3. GETTING STARTED

3.6 ANALOG AND RELAY OUTPUT CONNECTIONS (continued)Figure 3-11 Analog Output ConnectionsFigure 3-12 Isolated Analog Output Connections19

Pagina 23 - Figure 3-4 Panel Cut-Out

PREFACEManual ObjectivesThis manual shows you how to set up and use the Differential RTD Meter.Standard Procedures:* Checking voltage jumpers, or chan

Pagina 45

NOTES, WARNINGS and CAUTIONSInformation that is especially important to note is identified by these labels:• NOTE• WARNING• CAUTION• IMPORTANTNOTE: pr

Pagina 51

47Table 10-1 Front-Panel Displays (continued)/DEVMENUDESCRIPTION/T1/T2/Table 10-2 Run Mode Display/DEVDISPLAYDESCRIPTION/T1/T2/RESETRunModeLAT

Pagina 52

48SECTION 11. SETPOINT CONFIGURATION DISPLAYSTable 11-1 Setpoints Configuration DisplaysSP 1Setpoint 1SETPOINT 1Select from -1999through 9999SETPOINT

Pagina 53

SECTION 12. SPECIFICATIONSSIGNAL INPUTRTD types: DIN (0.00385) type 2,3, or 4 wireNIST (0.00392) type 2,3, or 4 wireLead Resistance for Specified Acc

Pagina 54

INPUT POWER INFORMATION:~ AC units 115/230 V~(AC) ±10%, 50/60 Hz7 W max, power consumption (Non-Isolated AnalogOutput)8 W max, power consumption (Isol

Pagina 55 - Changes the value

ANALOG OUTPUT (if applicable)Signal type: Current or voltageSignal level: Current: 10 V max compliance at 20 mA outputVoltage: 20 mA max for 0-10 V ou

Pagina 56

ivTable of ContentsSectionPage1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1 UN

Pagina 57 - SECTION 12. SPECIFICATIONS

SIDE VIEWTOP VIEWCASEREAR COVER96,0 (3.78)48,0 (1.89)20,3 (.80)151,4 (5.96)RETAINERFRONT BEZEL45,00 + 0,61/-0,00(1.772 + .024/–.000)92,00 + 0,81/–0

Pagina 58 - MECHANICAL

MENU ITEM FACTORY PRESET VALUESINPT Input Type: 385.3 (3 wire DIN RTD)DEC.P Decimal Point Position: FFF.FRD.CF Reading Configuration:R.1=F (Fahrenhei

Pagina 59 - ALARM OUTPUTS (if applicable)

CE APPROVALS INFORMATIONThis product conforms to the EMC directive 89/336/EEC amended by93/68/EEC, and with the European Low Voltage Directive 72/23/E

Pagina 60 - Figure 12-1 Meter Dimensions

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1)year from the

Pagina 61 - 0-1000 = 4-20 mA dc

M1865/0206 11869ML-96 Rev.BWhere Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop on line at www.omega.comTEMPERA

Pagina 62 - CE APPROVALS INFORMATION

vSectionPage4.8 SELECTING OUTPUT CONFIGURATION (OT.CF) . . . . . . . . . . . . . .264.8.1 Enabling or Disabling The Analog Output . . . . . . . .

Pagina 63 - RETURN REQUESTS/INQUIRIES

viList of FiguresFigureFigure 2-1. Front-Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Figure 2-3.

Pagina 64 - Shop on line at www.omega.com

1SECTION 1. INTRODUCTION1.1 UNPACKINGRemove the Packing List and verify that all equipment has been received. If there areany questions about the sh

Commenti su questo manuale

Nessun commento