Omega RD100B Manuale Utente

Navigare online o scaricare Manuale Utente per Registratori vocali Omega RD100B. Omega RD100B User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - User’s Guide

RD100BProgrammable Recorderomega.com e-mail: [email protected] latest product manuals:omegamanual.infoShop online atUser’s Guide

Pagina 2 - ISO 9001 Cer

viiiHow to Use This ManualThis user’s guide consists of the following sections.For details on communication functions, see the RD100B/RD1800B Communic

Pagina 3 - Revisions

5-61-5V InputSelect 1-5V.Set the channel range.Set the left span value.Set the right span value.Set the left scale value.Set the right scale value.Tur

Pagina 4 - Software (Sold Separately)

5-7Frequently Used Setup Operations (Setting Mode)5Square Root ComputationSelect SQRT.Set the channel range.Select the range type of DC voltage.20 mV,

Pagina 5 - Safety Precautions

5-8Note• The displayable/printable range of scale values is –19999 to 30000 excluding the decimal.• If the leftmost value of the scale is set to –2000

Pagina 6 - Exemption from Responsibility

5-9Frequently Used Setup Operations (Setting Mode)55.2 Setting the AlarmThe alarm is set for each channel.If you change the input range, set the alarm

Pagina 7 - Checking the Model

5-10ExplanationChannel RangeThe only case when an alarm can be set on multiple channels simultaneously is whenthe channels are set to the same range t

Pagina 8 - Standard Accessories

5-11Frequently Used Setup Operations (Setting Mode)5NoteFor channels whose the leftmost value of the scale is set to –20000 (excluding the decimal),th

Pagina 9 - Tab on the display

5-125.3 Setting the Unit on Scaled ChannelsUnits are set on channels whose input range is set to Scaling, 1-5V, or SQRT.Procedure1. Hold down the MENU

Pagina 10 - How to Use This Manual

5-13Frequently Used Setup Operations (Setting Mode)55.4 Changing the Chart SpeedThis section explains the details of changing the chart speed.Procedur

Pagina 11

5-145.5 Setting the Date/TimeThis section explains the details of setting the date/time.Procedure1. Hold down the MENU key for 3 seconds to enter Sett

Pagina 12 - Contents

6-1Setup Operations for Convenient Functions (Setting Mode)66.1 Setting the Trend Recording Interval (DotModel).This section explains the details of s

Pagina 13

ix123456789101112AppIndexConventions Used in This ManualUnitK ... Denotes 1024. Example: 768 KB (file size)k ... Denotes 1000.Safety Markin

Pagina 14 - Appendix

6-26.2 Setting the Filter (Pen Model)This section explains the details of setting a filter on the measurement channels on thepen model.Procedure1. Hol

Pagina 15 - 1.1 Overview of the Recorder

6-3Setup Operations for Convenient Functions (Setting Mode)66.3 Setting the Moving Average (Dot Model)This section explains the details of setting the

Pagina 16 - 1.2 Measuring Input Section

6-46.4 Setting Recording Zones for Each Channel(Zone Recording)This section explains the details of setting the recording zone for each measurementcha

Pagina 17 - Measured value

6-5Setup Operations for Convenient Functions (Setting Mode)66.5 Setting the Partial Expanded RecordingThis section explains the details of expanding a

Pagina 18

6-66.6 Turning Trend Recording (Dot Model) andPeriodic Printout ON/OFF for Each ChannelThis section explains the details of setting the trend recordin

Pagina 19

6-7Setup Operations for Convenient Functions (Setting Mode)66.7 Setting Tags on ChannelsThis section explains the details of setting tags to measureme

Pagina 20

6-86.8 Setting the Message StringThis section explains the details of setting the message strings to be printed on the chartpaper. Up to five message

Pagina 21 - 1.3 Alarms

6-9Setup Operations for Convenient Functions (Setting Mode)66.9 Setting the Secondary Chart Speed (RemoteControl Function, /R1)This section explains t

Pagina 22

6-106.10 Setting the Alarm Delay DurationThis section explains the details of setting the duration of the delay alarm.Procedure1. Hold down the MENU k

Pagina 23 - Alarm Recording

6-11Setup Operations for Convenient Functions (Setting Mode)66.11 Setting the Brightness of the Display andInternal LightThis section explains the det

Pagina 25 - NO C NC NO C NCNO C

6-126.12 Applying a Bias on the Measuring Input SignalThis section explains the details of setting a bias on the measuring input signal.If you change

Pagina 26 - Alarm ACK Operation

6-13Setup Operations for Convenient Functions (Setting Mode)66.13 Setting the Date/Time When Switching betweenStandard Time and DSTThis section explai

Pagina 27 - 1.4 Recording

6-14ESC/?Select Use.Month, day of the week, and time when the DST starts. MonthThe n th day of the weekof the monthThe n th day of the weekof the mon

Pagina 28 - Zone 1 Zone 2 Zone 3

6-15Setup Operations for Convenient Functions (Setting Mode)6Recorders with Version 1.02 or EarlierThe following is the setting menu.Select standard t

Pagina 29 - Same time

7-1Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.1 Changing the Auxiliary Alarm FunctionThis section explains the details of s

Pagina 30 - Printout

7-2Select On to set relays I01, I02, and I03 to reflash alarm operation.Select On to set relay I01 to diagnosis output.Select the range of relays that

Pagina 31

7-3Setup Operations for Changing/Adding Functions (Basic Setting Mode)7ReflashTurns On/Off the reflash alarm operation of alarm output relays I01, I02

Pagina 32

7-47.2 Changing the Integration Time of the A/DConverterThis section explains the details of setting the integration time of the A/D converter.Basic S

Pagina 33

7-5Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.3 Setting the Burnout Detection Function ofThermocouplesThis section explains

Pagina 34

7-67.4 Setting the RJC Function on Channels Set toTC InputThis section explains the details of setting RJC on channels set to TC input.Basic Setting m

Pagina 35 - 1.4 Recording

xi123456789101112AppIndex5.4 Changing the Chart Speed ... 5-1

Pagina 36 - 1 2 3 4 5 6KEY LOCK

7-7Setup Operations for Changing/Adding Functions (Basic Setting Mode)7ExplanationRJCSets the RJC mode.Internal: Uses the RJC function on the recorder

Pagina 37 - Bar graph

7-87.5 Changing the Channel Recording Color (DotModel)This section explains the details of changing the trend recording color on the dot model.Basic S

Pagina 38 - Types of Computations

7-9Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.6 Recording by Compensating for the Pen Offsetalong the Time Axis (Pen Model)

Pagina 39 - Pen 1 2 3 4

7-107.7 Turning Printouts ON/OFF.This section explains the details of turning ON/OFF the printouts of various items.Basic Setting mode cannot be enter

Pagina 40 - Starting/Stopping Computation

7-11Setup Operations for Changing/Adding Functions (Basic Setting Mode)7Applying the Changes and Returning to Operation ModePress the key or SHIFT +

Pagina 41 - (/F1 Option)

7-127.8 Setting the Periodic Printout Interval and theType of Measured Values to Be PrintedThis section explains the details of setting the periodic p

Pagina 42 - Open collector

7-13Setup Operations for Changing/Adding Functions (Basic Setting Mode)7Types of Report Data to Be PrintedChanging the Settings1. Hold down the MENU k

Pagina 43

7-14ExplanationPeriodic Printout IntervalPeriodicSelect the periodic printout interval mode.Auto: Automatically sets the printout interval in sync wit

Pagina 44 - 1.9 Other Functions

7-15Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.9 Setting the Bar Graph Display ModeThis section explains the details of set

Pagina 45 - 2.1 Handling Precautions

7-167.10 Setting the Key Lock FunctionThis section explains the details of setting the keys that can be locked and the passwordfor releasing the key l

Pagina 46 - 2.2 Installation

xiiContents9.8 Setting the Partial Expanded Recording ... 9-169.9 Turning Trend R

Pagina 47 - Installation Procedure

7-17Setup Operations for Changing/Adding Functions (Basic Setting Mode)7ESC/?Set the password for releasing the key lock.Select whether to use the key

Pagina 48 - 2.2 Installation

7-18Applying the Changes and Returning to Operation ModePress the key or SHIFT + key to select End and then press the key. Pressthe key to sel

Pagina 49 - 2.3 Input Signal Wiring

7-19Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.11 Enabling the Moving Average Function (DotModel)This section explains the

Pagina 50 - Terminal cover

7-207.12 Enabling the Filter Function (Pen Model)This section explains details of enabling/disabling the input filter function on the penmodel.Basic S

Pagina 51

7-21Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.13 Enabling the Partial Expanded RecordingFunctionThis section explains the

Pagina 52 - Measuring Input Wiring

7-227.14 Changing the Display/Recording LanguageThis section explains the details of changing the display/recording language.Basic Setting mode cannot

Pagina 53 - 2.4 Optional Terminal Wiring

7-23Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.15 Enabling the Bias Function, Low-Cut Function,and Alarm Delay FunctionThis

Pagina 54

7-24ExplanationBiasEnables/Disables the bias function.Use: Enables the setting of the bias value in Setting mode.Not: The Bias item does not appear in

Pagina 55 - Crimp-on lug with

7-25Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.16 Changing the Time Printout FormatThis section explains the details of cha

Pagina 56 - 2.5 Power Supply Wiring

7-26ExplanationAlarmsSets the time printout format of the alarm printout.HH:MM: Hour:MinuteHH:MM:SS: Hour:Minute:SecondM/D H:M: Month Day Hour:MinuteM

Pagina 57 - Wiring Procedure

1-1Functional Description11.1 Overview of the RecorderThe RD100B Recorder (hereafter referred to as the recorder) can be used to assign DCvoltage, 1-5

Pagina 58

7-27Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.17 Initializing the SettingsThis section explains the details of initializin

Pagina 59 - 3.1 Names of Parts

7-287.18 Assigning Functions to the Remote ControlInput Terminals (/R1 Option)This section explains the details of assigning functions to the input te

Pagina 60 - Display and Key Panel

7-29Setup Operations for Changing/Adding Functions (Basic Setting Mode)7ExplanationRemote No.The remote control terminal numbers are from 1 to 5.Funct

Pagina 61 - Rear Panel

7-307.19 Changing the Printout/Display Format of theDateThis section explains how to change the printout/display format of the year, month, andday.Bas

Pagina 62 - Loading the Chart Paper

7-31Setup Operations for Changing/Adding Functions (Basic Setting Mode)77.20 Changing the Temperature UnitThis section explains the details of changin

Pagina 63 - Sprocket teeth

8-1Setup Operations for Changing the Displayed Contents88.1 Key Operations for Changing the DisplayedInformationDisplaying the Data Display Setup Scre

Pagina 64

8-2Data Display Setup MenuThis menu is used to assign display types to screen 01 to 15. The indicates adisplay type. The items to set for each typ

Pagina 65 - (Pen Model)

8-3Setup Operations for Changing the Displayed Contents88.2 Changing the Displayed InformationThis section explains the details of registering display

Pagina 66 - Func=Pen exchange

9-1Operations Related to the Computation Function (/M1 Option)99.1 Starting/Stopping/Resetting the ComputationThis section explains the details of sta

Pagina 67 - Func=R. exchange

9-29.2 Setting the Computing EquationThe computing equation cannot be entered when the computation is in progress. If youchange the computing equatio

Pagina 68 - Ribbon feeding knob

1-21.2 Measuring Input SectionInput SectionNumber of Measurement Channels and Scan IntervalThe recorder samples the input signals on the measurement

Pagina 69 - Recorded chart paper can

9-3Operations Related to the Computation Function (/M1 Option)9Each time you press the CHARACTER key the display changes as shown below.Pressing the

Pagina 70

9-4ExplanationComputing EquationFollow the rules below when writing computing equations.• Use up to 120 characters to write equations.• The precedence

Pagina 71 - Print=Manual Stop

9-5Operations Related to the Computation Function (/M1 Option)9• Status of the Remote Control Input Terminal (D01 to D05, /R1 option)The status of the

Pagina 72 - Print=Setup Stop

9-6Relational ComputationThe data that can be used in equations are measured values, computed values,constants, communication input data, and remote c

Pagina 73 - Buf.clear=Alarm

9-7Operations Related to the Computation Function (/M1 Option)9ORLogical sum(Syntax) e1ORe2(Condition) If the two data values e1 and e2 are both zeroe

Pagina 74 - 3.10 Printing Messages

9-8TLOG ComputationOnly measured values and computed values can be used in TLOG computation. In theexplanation below, e1 is used to represent a measu

Pagina 75

9-9Operations Related to the Computation Function (/M1 Option)99.3 Setting the UnitThis section explains the details of setting the unit on computatio

Pagina 76 - Operation)

9-109.4 Setting the Constants Used in EquationsThis section explains the details of setting constants to be used in computing equations.Procedure1. Ho

Pagina 77 - Password=

9-11Operations Related to the Computation Function (/M1 Option)99.5 Setting the AlarmThis section explains the details of setting alarms for each comp

Pagina 78 - 4.1 Run Modes

9-12ExplanationAlarm TypeSymbol NameH High limit alarmL Low limit alarmT Delay high limit alarm*t Delay low limit alarm** Selectable only when the ala

Pagina 79 - 4.2 Key Operations

1-3Functional Description1• Delta ComputationThe value obtained by subtracting the measured value of another channel (called thereference channel) fro

Pagina 80 - SHIFT key + key

9-13Operations Related to the Computation Function (/M1 Option)99.6 Specifying the Timer Used in StatisticalCalculations (TLOG)On channels that perfor

Pagina 81

9-14ExplanationTimer No.There are three timers.Periodic: The timer for determining the periodic printout interval. The computed resultis printed ever

Pagina 82

9-15Operations Related to the Computation Function (/M1 Option)99.7 Setting Recording Zones for Each Channel(Zone Recording)This section explains the

Pagina 83

9-169.8 Setting the Partial Expanded RecordingThis section explains the details of expanding a section of the recording range.If you change the comput

Pagina 84

9-17Operations Related to the Computation Function (/M1 Option)99.9 Turning Trend Recording (Dot Model) andPeriodic Printout ON/OFF for Each ChannelTh

Pagina 85

9-189.10 Setting Tags on ChannelsThis section explains the details of setting the tag on computation channels.Procedure1. Hold down the MENU key for 3

Pagina 86 - . - 120 characters or less 01

9-19Operations Related to the Computation Function (/M1 Option)99.11 Setting the Alarm Delay DurationThis section explains the details of setting the

Pagina 87

9-209.12 Setting the Timer Used in TLOG Computationand Periodic PrintoutThis section explains the details of setting the timer used in TLOG computatio

Pagina 88 - SQRT low-cut - Not/Use Use

9-21Operations Related to the Computation Function (/M1 Option)9Applying the Changes and Returning to Operation ModePress the key or SHIFT + key t

Pagina 89

9-22ResetSelects whether to reset the TLOG computed value at each interval. The figure belowillustrates the reset operation for sum computation (TLOG

Pagina 90 - 4.4 Function Setup Guide

1-4BiasA given value (bias value) is added to the input value and used as the measured value ofthat channel.Input valueBias valueBiased channelMeasure

Pagina 91 - 4.4 Function Setup Guide

9-23Operations Related to the Computation Function (/M1 Option)99.13 Changing the Channel Recording Color (DotModel)This section explains the details

Pagina 92

9-249.14 Changing the Channel Assignments ofRecording Pens (Pen Model)Measurement channels and computation channels can be arbitrarily assigned toreco

Pagina 93

9-25Operations Related to the Computation Function (/M1 Option)99.15 Changing the Type of Report Data Printed inPeriodic PrintoutThis section explains

Pagina 94

9-26ExplanationModeSets the type of report data to be printed.AVE: Prints the average value over the interval.MIX: Prints the minimum, maximum, and av

Pagina 95 - 5.1 Setting the Input Range

9-27Operations Related to the Computation Function (/M1 Option)99.16 Setting the Bar Graph Display ModeThis section explains the details of setting th

Pagina 96 - 5.1 Setting the Input range

9-289.17 Setting the Procedure Taken When theComputed Result Is in ErrorThis section explains the details of setting the procedure taken when the comp

Pagina 97 - Linear Scaling

9-29Operations Related to the Computation Function (/M1 Option)9ExplanationErrorSpecifies how to display or print the computed result when computation

Pagina 98 - Delta Computation

10-1Troubleshooting1010.1 A List of Error MessagesThere are cases in which error codes and messages are displayed on the screen duringoperation. The

Pagina 99 - ON/OFF Input

10-2Code Message Explanation/Countermeasures72 MATH channel is turned off –81 All space or ‘quit’ string cannot be specified. –86 The key-lock release

Pagina 100 - 1-5V Input

10-3Troubleshooting10Code Message Explanation/Countermeasures400 Input username. –401 Input password. –402 Select username from ‘admin’ or ‘user’. If

Pagina 101 - Square Root Computation

1-5Functional Description1Noise Elimination from Input SignalsFilter and Moving AverageThis function used to suppress the effects of noise that is rid

Pagina 102 - Skip (Unused Channels)

10-410.2 Troubleshooting Flow ChartsFollow the flow charts to correct the problem.Is the power supply connected properly?Is the power supplied properl

Pagina 103 - 5.2 Setting the Alarm

10-5Troubleshooting10NONONOYESYESYESIs the input wiring correct?• Attach the input terminal cover properly.• Protect the input terminal from wind or

Pagina 104

10-6Is the input free of noise?NOYES• Separate the input and communication wiring from the noise source.• Ground the recorder properly.• Use shiel

Pagina 105

11-1Maintenance1111.1 Periodic InspectionCheck the operation periodically to keep the recorder in good working order.Perform the following checks and

Pagina 106 - The new setting takes effect

11-211.2 Cleaning the RecorderCAUTION• When cleaning, be sure not to scratch the flexible printed circuit board of theplotter carriage.• Do not apply

Pagina 107 - 5.4 Changing the Chart Speed

11-3Maintenance1111.3 Replacing the Internal Light LEDIf the brightness of the internal light degrades with time, replace the LED.For the replacement

Pagina 108 - 5.5 Setting the Date/Time

11-411.4 Calibrating the RecorderCalibrate the measured value against the input.It is recommended that the recorder be calibrated once a year to assur

Pagina 109

11-5Maintenance11Temperature Measurement When Using an RTDDecade resistance boxThe resistance of three lead wires must be equal.+/A/bInput terminals−/

Pagina 110 - Last channel

11-611.5 Adjusting the Pen Position (Pen Model)This section explains the details of adjusting the pen position on the chart paper.It is recommended th

Pagina 111

11-7Maintenance1111.6 Adjusting the Dot Printing Position (Dot Model)This section explains the details of adjusting the dot printing position on the c

Pagina 112 - (Zone Recording)

Servicing North America:U.S.A.: One Omega Drive, P.O. Box 4047ISO 9001 CertifiedStamford, CT 06907-0047TEL: (203) 359-1660 FAX: (203) 359-7700e-mail:

Pagina 113

1-6Integration Time of the A/D ConverterThe recorder uses an A/D converter to convert the sampled analog signal to a digitalsignal. By setting the in

Pagina 114

11-87. Press the ESC key to finish the adjustment. The screen returns to theBasic=P_Adj screen.Select Zero or Full.Change the value to adjust the pen

Pagina 115 - 6.7 Setting Tags on Channels

11-9Maintenance1111.7 Recommended Replacement Periods for WornPartsTo preserve the reliability of the recorder and to use the recorder in good conditi

Pagina 116 - Set message string

11-10Dot ModelNote33 days3 monthsB9962EJCARRIAGE ASSY5 yearsItemReplacement Period Part Name Part No.Ribbon feed motorZ-fold chart paper CH

Pagina 117 - Control Function, /R1)

12-1Specifications1212.1 Input SpecificationsNumber of Inputs and Scan Interval on the Pen ModelItem SpecificationsNumber of inputs 1, 2, 3, or 4Scan

Pagina 118

12-2Item SpecificationsInput type Floating unbalanced input.Isolation between channels (except, b terminal is shared for RTD input).Burnout Detection

Pagina 119 - Internal Light

12-3Specifications1212.2 Alarm Function SpecificationsItem SpecificationsNumber of alarms Up to four alarms (level) for each measurement channels.Alar

Pagina 120 - Set the bias value

12-412.3 Recording Function SpecificationsTrend Recording (Pen Model)Item SpecificationsRecording pen Disposable felt penStep response time Approx. 1

Pagina 121 - Standard Time and DST

12-5Specifications12Printouts (Pen Model)Item SpecificationsRecording pen (color) Plotter pen (purple)Alarm printout Prints alarm occurrence/release.P

Pagina 122

12-6Printout (Dot Model)Item SpecificationsRecording Dot printing.Channel printout Prints the channel number beside the trend recording every approx.

Pagina 123 - Set the time to switch

12-7Specifications1212.4 Display Function SpecificationsDisplay and Displayed ContentsThis section explains the specifications of the display function

Pagina 124

1-7Functional Description11.3 AlarmsThis function generates an alarm when the measured data meets a certain condition.The alarm occurrence/release can

Pagina 125 - (models with /M1)

12-8Item SpecificationsDisplay type specificationsDigital displayMeasured value or computed value• DC voltage input: Displays values between “the min.

Pagina 126

12-9Specifications12Item SpecificationsBar graph display Displays the measured value on a bar graph.Relationship between the digital display and bar g

Pagina 127 - Converter

12-10Name Display Example Description1-channel digital display2-channel digital display4-channel digital display6-channel digital display(Dot model)4-

Pagina 128 - Thermocouples

12-11Specifications12Name Display Example DescriptionTagAlarm MeasuredvalueUnitMeasurement channelMeasurement channelMeasurement channelComputation ch

Pagina 129 - TC Input

12-12Name Display Example DescriptionMultiple display (Different screens assigned to the top and bottom sections)Chart speed1-channel digital display2

Pagina 130

12-13Specifications1212.5 Specifications of Optional FunctionsAlarm Output Relay (/A1, /A2, and /A3)Item SpecificationsOperation Outputs relay contact

Pagina 131 - Select the recording color

12-14FAIL/Chart End Detection and Output (/F1)Item SpecificationsFAIL output Relay output on CPU errorRelay operation Energized during normal operatio

Pagina 132

12-15Specifications12AlarmsNumber of alarms Up to four alarms (level) for each measurement channels.Alarm types High limit (H), low limit (L), delay h

Pagina 133 - 7.7 Turning Printouts ON/OFF

12-16Item SpecificationsMeasurement and recording accuracy Input Type Measurement Accuracy Recording Accuracy PR40-20 0 to 450°C Not warranted 450

Pagina 134

12-17Specifications1212.6 General SpecificationsConstructionItem SpecificationsMounting Flush panel mounting (on a vertical plane)Mounting angle Incli

Pagina 135 - Periodic Printout Interval

1-8• Delay High Limit Alarm (T)An alarm occurs when the measured value remains above the alarm value for aspecified time period (alarm delay period).•

Pagina 136 - Select the sum scale

12-18IsolationItem SpecificationsInsulation resistance Each terminal to ground terminal: 20 MΩ or more (at 500 VDC)Dielectric strength Power supply to

Pagina 137

12-19Specifications12Standard PerformanceItem SpecificationsMeasurement and recording accuracyThe following specifications apply to operation of the r

Pagina 138

12-20Item SpecificationsReference junction compensation accuracyAbove 0°C with input terminal temperature balanced (60 minutes after power on)Type R,

Pagina 139

12-21Specifications1212.7 Dimensional Drawings220 (8.66)(1.08) 27.5178 (7.01)136.5(5.37)+207.59.42 to 26Mounting panel thickness(Dimensions before att

Pagina 140 - (Dot model)

App-1Periodic Printout and Printout Using the TLOG Timer (/M1 Option)AppAppendixAppendix 1 Periodic Printout and Printout Using theTLOG Timer (/M1 Opt

Pagina 141

App-2• ScalePrints the leftmost and rightmost values of the recording span and the channelnumber or tag for channels that have scale printout specifie

Pagina 142

App-3Periodic Printout and Printout Using the TLOG Timer (/M1 Option)AppDot ModelInstantaneous ModePrints the letter “d” for channels set todelta comp

Pagina 143

App-4Printout Using the TLOG Timer (/M1 Option)Prints the computed values of computation channels for each interval determined by theTLOG timer.Pen Mo

Pagina 144 - Function

App-5Periodic Printout and Printout Using the TLOG Timer (/M1 Option)AppSpecial CasesThis section explains the operation of the periodic printout repo

Pagina 145

Index-1IndexIndexIndexchart speed ... 1-14, 5-13cleaning ...

Pagina 146

1-9Functional Description1Alarm IndicationThe alarm status can be displayed on the screen. For details on the display, see section1.5.Non-Hold/Hold O

Pagina 147

Index-2F PageFAIL output ... 1-27fastest recording interval ...

Pagina 148

Index-3IndexIndexR Pagerange type ... 1-2rear panel ...

Pagina 149

Index-4

Pagina 150 - Are you sure?=No

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for aperiod of 13 months from date of

Pagina 151 - Input Terminals (/R1 Option)

M4231/0805Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop online at omega.comTEMPERATUREMUThermocouple, RT

Pagina 152

1-10Reflash AlarmWhen multiple alarms are assigned to one alarm output relay, this function notifies theoccurrence of subsequent alarms after the rela

Pagina 153 - Select the date format

1-11Functional Description1AND/OR Operation of Alarm Output RelaysWhen multiple alarms are assigned to one alarm output relay, the condition for activ

Pagina 154 - Select the temperature unit

1-12Non-Hold/Hold Operation of Alarm Output RelaysThe alarm output relay can be set to operate in the following fashion when the alarmcondition is no

Pagina 155 - Information

1-13Functional Description11.4 RecordingThe recorder is capable of recording the measured values with pens or dots (trendrecording) as well as various

Pagina 156 - Data Display Setup Menu

1-14Trend RecordingThe measured values are printed within a width of 100 mm.Recording Method (Pen Model)• The measured value is updated every scan int

Pagina 157 - 1 200.0 mV

1-15Functional Description1Partial Expanded RecordingThis function expands a section of the recording range. By default, partial expandedrecording is

Pagina 158 - Math=Reset

iForewordThank you for purchasing the OMEGA RD100B Recorder.This manual describes the functions (excluding the communication functions), installationa

Pagina 159

1-16PrintoutThe figure below is used to explain the printout contents. The actual printout and fontare different from those illustrated in the figure

Pagina 160 - CHARACTER

1-17Functional Description1Printout Example on the Dot ModelAlarm printoutMessage printoutManual printoutChannel printoutPeriodic printoutScaleBuffer

Pagina 161 - Computing Equation

1-18Alarm PrintoutAlarm information is printed when an alarm occurs or releases.Time of alarm occurrence/releaseIndicates that there are alarms that a

Pagina 162 - Power and Other Computations

1-19Functional Description1• Turning ON/OFF the Periodic PrintoutPeriodic printout can be turn ON/OFF. By default, periodic printout is enabled with

Pagina 163 - Logical Computation

1-20Setting PrintoutList or Setup List can be printed. When setting printout is executed, trend recordingstops and restarts when the printout is comp

Pagina 164

1-21Functional Description1• Printout Example of List on the Dot ModelThe printout examples may appear differently from the actual printout as a resul

Pagina 165 - TLOG Computation

1-221.5 DisplayDisplayed InformationMain DisplayThe recorder is capable of displaying measured values, alarm information, and so on theVFD (Vacuum Flu

Pagina 166 - 9.3 Setting the Unit

1-23Functional Description1Several display examples are shown below. For details on the display types, see“Display Function Specifications” in sectio

Pagina 167 - Set the value

1-241.6 Computation Function (/M1 Option)Computation FunctionComputing equations can be set up using measured values and other computed valuesas varia

Pagina 168 - 9.5 Setting the Alarm

1-25Functional Description1• Communication Input Data (Pen model: C01 to C08, dot model: C01 to C12)This data type is set using the communication inte

Pagina 169

iiRecorder’s Version and Functions Described in ThisManualThe contents of this manual corresponds to the recorder with version 1.11.RD100B Versions an

Pagina 170 - Calculations (TLOG)

1-26• The Number of Channels Being Trend Recorded and the Fastest RecordingIntervalThe fastest recording interval varies depending on the number of ch

Pagina 171

1-27Functional Description11.7 FAIL/Chart End Detection and Output Function(/F1 Option)FAIL OutputWhen a failure occurs in the CPU of the recorder, a

Pagina 172

1-281.8 Remote Control Function (/R1 Option)Specified operations can be carried out by applying remote signals (contact or opencollector signals) to t

Pagina 173

1-29Functional Description1• Computation Start/Stop• Remote input signal: Rising edge signifies start; falling edge signifies stop• Starts/stops the c

Pagina 174

1-301.9 Other FunctionsKey LockKey lock is a function that prohibits key operations. When key lock is enabled, pressingkeys produces no effect. To r

Pagina 175 - 9.10 Setting Tags on Channels

2-1Before Using the Recorder22.1 Handling PrecautionsThis section describes the precautions to be taken when using the recorder. Read thissection bef

Pagina 176 - Set the alarm delay time

2-22.2 InstallationInstallation LocationInstall the recorder indoors in a location that meets the following conditions. See alsothe normal operating

Pagina 177

2-3Before Using the Recorder2Installation ProcedureThe recorder should be mounted on a steel panel of thickness 2 mm to 26 mm.1. Insert the recorder f

Pagina 178 - Interval Interval

2-4External Dimensions of the Recorder220 (8.66)(1.08) 27.5178 (7.01)136.5(5.37)+207.59.42 to 26Mounting panel thickness(Dimensions before attaching t

Pagina 179 - Reset: Off

2-5Before Using the Recorder22.3 Input Signal WiringGeneral Precautions to Be Taken While WiringWARNINGTo prevent the possibility of electric shock wh

Pagina 180

iiiSafety PrecautionsThe general safety precautions described here must be observed during all phases of operation.Safety Standards and EMC StandardsT

Pagina 181 - Recording Pens (Pen Model)

2-6When using internal reference junction compensation on the thermocouple input,take measures to stabilize the temperature at the input terminal.• Al

Pagina 182 - Periodic Printout

2-7Before Using the Recorder2Dot Model+/A–/Bb+/A–/BbChannel 1Channel 2Channel 3Channel 4Channel 5Channel 6Channel 1Channel 3Channel 5Channel 2Channel

Pagina 183

2-8Measuring Input Wiring––DC voltage1-5VON/OFFExtension leadwireDC currentShunt resistor–/Bb +/A –/Bb +/A–/Bb +/A –/Bb +/A++Thermocouple input Resist

Pagina 184

2-9Before Using the Recorder22.4 Optional Terminal WiringGeneral Precautions to be Taken While Wiring the Input/Output Signal WiresWARNING• To prevent

Pagina 185 - Computed Result Is in Error

2-10NO C NCNO CNC/A1NO C NCNO C NCNO C NCNO CNC/A1/F1 /A1/R1I01I02I01I02I01I02CEFAILNO C NCNO CNC12345C/A1/F1/R1NO C NCNO C NCNO C NCNO CNCI01I02CEFAI

Pagina 186

2-11Before Using the Recorder2Wiring Procedure1. Turn OFF the recorder and remove the terminal cover.2. Connect the input signal wires to the terminal

Pagina 187 - 10.1 A List of Error Messages

2-122.5 Power Supply WiringPrecautions to Be Taken While Wiring the Power SupplyMake sure to follow the warnings below when wiring the power supply.

Pagina 188 - Communication Errors

2-13Before Using the Recorder2Wiring ProcedureThe power supply terminals and a protective ground terminal are located on the rearpanel.1. Turn OFF the

Pagina 189 - System Errors

2-142.6 Turning ON/OFF the Power SwitchCAUTIONCheck the following points before turning ON the power switch.• The power cord/wires are connected corre

Pagina 190

3-1Names of Parts and Run Operations33.1 Names of PartsFrontDoorName plateThe model name is writtenon the name plate.Power switchTurns ON/OFF the powe

Pagina 191 - Troubleshooting

ivWARNING• Power SupplyEnsure that the source voltage matches the voltage of the power supply before turning ON the power.• Protective GroundingMake s

Pagina 192

3-2Display and Key PanelRCDMENU FEEDCH UPFUNCMENUDISP1CHARACTERRECORD MATH CHART END ALARM1 2 3 4 5 6KEY LOCKESC/?SHIFTMain displayDisplays

Pagina 193 - 11.1 Periodic Inspection

3-3Names of Parts and Run Operations3Rear PanelMeasuring input terminal blockMeasuring input terminalsHeatsinkDissipates the internal heat.Optional te

Pagina 194 - 11.2 Cleaning the Recorder

3-43.2 Installing or Replacing the Chart PaperCAUTION• Do not install or remove the chart cassette with the chart paper guide open.This may damage the

Pagina 195 - Display and key panel

3-5Names of Parts and Run Operations33. Open the chart holder and the chart paper guide.Chart holderThis sheet is provided on modelswith the chart end

Pagina 196 - 11.4 Calibrating the Recorder

3-66. Replace the chart cassette back into the recorder case.Align the left and right projections of the sprocket section with the guide groovesof the

Pagina 197

3-7Names of Parts and Run Operations33.3 Installing/Replacing Felt Pens or Plotter Pen(Pen Model)CAUTION• Do not press or pinch the felt tip to preven

Pagina 198 - The pen moves

3-8When the Pen (Pen Holder) Is at a Position That Is Not Easily AccessibleIf the pen (pen holder) is at a position that is not easily accessible, car

Pagina 199 - Figure a Figure b

3-9Names of Parts and Run Operations33.4 Installing/Replacing the Ribbon Cassette (DotModel)CAUTION• Improper cassette insertion may cause the color t

Pagina 200

3-107. Install a new ribbon cassette.First, insert the right-hand part and then the left-hand part into the cassette holder.Check that the cassette is

Pagina 201

3-11Names of Parts and Run Operations33.5 Starting/Stopping the RecordingThis section describes the procedures for starting/stopping the recording and

Pagina 202 - Dot Model

vChecking the Contents of the PackageUnpack the box and check the contents before operating the recorder. If some of thecontents are not correct or m

Pagina 203 - 12.1 Input Specifications

3-123.6 Switching the Display ScreenThis section describes the procedure for switching the display screen.To change the displayed content, see chapter

Pagina 204 - 12.1 Input Specifications

3-13Names of Parts and Run Operations33.7 Printing Measured Values (Manual Printout)The measured values of all channels are printed.ProcedureStarting

Pagina 205 - Specifications

3-143.8 Printing the Recorder SettingsThis section explains the procedure for printing the recorder settings. There are two setsof settings that can

Pagina 206 - Chart Paper

3-15Names of Parts and Run Operations33.9 Clearing the Alarm Printout BufferAlarm information waiting to be printed is temporarily stored in the buffe

Pagina 207

3-163.10 Printing MessagesThis section explains the procedure for printing the preset character strings. For theprocedure of setting the character st

Pagina 208

3-17Names of Parts and Run Operations33.11 Resetting the Report Data of the PeriodicPrintoutThis operation resets the past report data when the record

Pagina 209

3-183.12 Releasing the Alarm Output (Alarm ACKOperation)This operation releases the alarm indication or relay output (/A1, /A2, or /A3 option)when the

Pagina 210

3-19Names of Parts and Run Operations3* When the key or key is pressed while holding down the SHIFT key, the operation is reversed

Pagina 211 - MAC address: MAC address

4-1Common Operations for Setting Functions and Setup Guide44.1 Run ModesThe recorder has three run modes.Operation ModeThis mode is used for normal re

Pagina 212 - 1H3000.0ABC

4-24.2 Key OperationsThis section describes basic operations on the panel keys to change various settings.Functions are set in Setting mode or Basic S

Pagina 213

viStandard AccessoriesThe standard accessories below are supplied with the recorder. Check that all contentsare present and undamaged.Z-fold chart pa

Pagina 214 - Computation channel

4-3Common Operations for Setting Functions and Setup Guide4Changing the SettingsNoteThe comment line shows useful information such as a description of

Pagina 215

4-4Entering CharactersUse the key or SHIFT + key to move the cursor.SHIFT key + key keyCursorUnit=ppmCHR:a-zUse the CHARACTER key or S

Pagina 216 - Computation Function (/M1)

4-5Common Operations for Setting Functions and Setup Guide44.3 Menu Structure, Settings, and List of DefaultValuesOperation Menus Using the FUNC Key (

Pagina 217 - i = 1 mA)

4-6Pen exchange (Pen Model)Moves the recording pen to a position that is easily accessible for replacement on thepen model.R. exchange (Dot Model)Move

Pagina 218 - Remote Control 5 Points (/R1)

4-7Common Operations for Setting Functions and Setup Guide4Menu Structure of Setting ModeBelow are the setup items in Setting mode. Information indic

Pagina 219 - 12.6 General Specifications

4-8Menu Structure of Basic Setting ModeBelow are the setup items in Basic Setting mode. Information indicated inside theparentheses is references.Add

Pagina 220 - Supported Standards

4-9Common Operations for Setting Functions and Setup Guide4Setup Items in Setting Mode and Their Default ValuesItems with an asterisk on the left are

Pagina 221 - Standard Performance

4-10Setup Item Pen/Dot Selectable Range or Selections Default ValueMath > Unit > Unit - 6 characters or less BlankMath > Constant > No. -

Pagina 222 - Other Specifications

4-11Common Operations for Setting Functions and Setup Guide4Setup Item Pen/Dot Selectable Range or Selections Default ValuePrint2 > CH - 01 to 06 0

Pagina 223 - 12.7 Dimensional Drawings

4-12Setup Item Pen/Dot Selectable Range or Selections Default ValueMath > Color > Color Dot Model Purple/Red/Green/Blue/Brown/Black Purple: 0A/0

Pagina 224 - TLOG Timer (/M1 Option)

viiRemoving the Packing MaterialsOpen the door, put your finger on the tab at the lower left of the display, and open thedisplay.DisplayTab on the dis

Pagina 225 - Sum value

4-13Common Operations for Setting Functions and Setup Guide44.4 Function Setup GuideThis section explains the settings necessary to use various functi

Pagina 226

4-14Alarm functionsItem Description ReferenceSectionAlarms for each channel Use Alarm in Setting mode. 5.2Delay high limit alarm/delay low limit alarm

Pagina 227 - Pen Model

4-15Common Operations for Setting Functions and Setup Guide4Item Description ReferenceSectionPeriodic printoutMeasured valueScaleChannel number or tag

Pagina 228 - Special Cases

4-16Display functionsItem Description ReferenceSectionDisplay brightness Use Aux > Brightness > Display in Setting mode to set the display brigh

Pagina 229

4-17Common Operations for Setting Functions and Setup Guide4Item Description ReferenceSectionPeriodic printoutComputed valueScaleChannel number or tag

Pagina 230

5-1Frequently Used Setup Operations (Setting Mode)55.1 Setting the Input RangeInput range is set for each measurement channel. Set unused channels to

Pagina 231

5-2Description• Selectable Range of Input Range, Span Left, and Span RightThe input range, span left, and span right can be set in the range shown bel

Pagina 232

5-3Frequently Used Setup Operations (Setting Mode)5Linear ScalingSelect Scale.Set the channel range.Select Volt, TC, RTD, or DI.Select the range type.

Pagina 233 - RETURN REQUESTS/INQUIRIES

5-4Delta ComputationSelect Delta.Set the channel range.Set the reference channel.Set the left span value.Set the right span value.The new setting take

Pagina 234 - Shop online at omega.com

5-5Frequently Used Setup Operations (Setting Mode)5ON/OFF InputSelect DI.Set the channel range.Select Cont or Level.Set the left span value.Set the ri

Commenti su questo manuale

Nessun commento